KGD - MQ - 529 Biogas Analysis System Fast Response

KGD - MQ - 529 Biogas Analysis System Fast Response

KGD - MQ - 529 Biogas Analysis System

Fast Response Biogas Analysis System

Place of Origin:

CHINA

Brand Name:

KACISE

Certification:

CE

Model Number:

KGD-MQ-529

Contact Us
Request A Quote
Product Details
Measured Components:
CH4/CO2/H2S/O2
Measurement Range:
CH4: (0 - 100)%; CO2: (0 - 50)%; H2S: (0 - 9999) Ppm; O2: (0 - 25%) (All Ranges Are Optional)
Response Time:
T90≤60s (NDIR)
Optimal Flow Rate:
(0.7 - 1.2) L/min
Inlet Gas Pressure:
(2 - 50) KPa
Gas Requirements:
Dust - Free, Water - Free, Oil - Free
Highlight:

KGD - MQ - 529 Biogas Analysis System

,

Fast Response Biogas Analysis System

Payment & Shipping Terms
Minimum Order Quantity
1PCS
Packaging Details
each unit has individual box and all boxes are packed in standard packages or customers requests available
Delivery Time
5-8 work days
Payment Terms
L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability
1000 Piece/Pieces per Week negotiable
Product Description

KGD - MQ - 529 Biogas Analysis System

Product Introduction

The KGD - MQ - 529 Biogas Analysis System innovatively adopts the patented technology of biogas component measurement by dilution method. It dilutes biogas with high humidity and high H2S content, effectively avoiding the influence of water condensation on pipelines and sensors. At the same time, it reduces the concentration of H2S gas, prolongs the service life of the H2S sensor, and does not require a complex and expensive pretreatment unit.

KGD - MQ - 529 Biogas Analysis System Fast Response 0

Product Features

  • Reduces the water content of the sample gas after dilution, avoiding water condensation, and eliminating the need for a complex pretreatment unit.
  • Lowers the concentration of H2S gas after dilution, greatly extending the service life of the H2S sensor.
  • Equipped with an ultrasonic flow detection unit to simultaneously monitor the flow rates of the sample gas and dilution gas as well as the dilution ratio.
  • The NDIR and ECD sensors adopt a modular design, facilitating maintenance and replacement.
  • The cabinet and components are subject to anti - corrosion treatment, making it suitable for biogas measurement environments with high humidity and high H2S content.
  • Patented technology of biogas component measurement by dilution method.
  • The biogas analyzer has won the title of "National Key New Product".

Technical Parameters

Parameter Details
Measured Components CH4/CO2/H2S/O2
Measurement Range CH4: (0 - 100)%; CO2: (0 - 50)%; H2S: (0 - 9999) ppm; O2: (0 - 25%) (All ranges are optional)
Response Time T90≤60s (NDIR)
Optimal Flow Rate (0.7 - 1.2) L/min
Inlet Gas Pressure (2 - 50) kPa
Gas Requirements Dust - free, water - free, oil - free
Electrical Parameters Electrical parameters
Communication RS - 485/RS - 232, (4 - 20) mA
Power Supply AC220V, 50HZ

 