Attribute | Value |
---|---|
Measuring range | 0.1~3m |
Pressure range | -0.1MPa~32MPa |
Capacitance detection range | 10PF~500PF |
Supply voltage | 5~36 V DC |
Output signal | 4-20mA/RS485 |
Measurement accuracy | Level 0.1、0.2 、0.5 、1 |
Environment temperature | -40~85℃ |
Ranging resolution | 0.1mm |
Long stability | ≤0.1%FS/ year |
Protection class | IP67 |
The High Temperature and High Pressure Corrosion Resistant Capacitive Level Sensor is specifically engineered for boiler level monitoring applications. Designed to withstand extreme conditions, this sensor delivers reliable and accurate level measurement in high-temperature, high-pressure boiler systems. Its corrosion-resistant construction ensures long-term performance while maintaining operational safety and efficiency through precise real-time level data.
The capacitive liquid level sensor consists of two main components: the sensor probe and transmitter. The structure varies based on application requirements.
A: Sensor probe that extends into the container or measuring tube
B & C: Gas phase and liquid phase connection flanges for equipment interface
D: Measuring cylinder that forms capacitance with the sensor electrode
E: Drain flange for periodic cleaning to maintain measurement accuracy
F: Transmitter that converts capacitance changes to 4-20mADC standard signal
The KSLV606 display model supports two wiring methods:
RS485 Connection:
4-20mA Connection:
Installation Note: Always open the gas phase valve first, followed by the liquid phase valve to prevent measurement errors from liquid level fluctuations. Ensure cable connections are secure and corrosion-resistant. Regular maintenance includes periodic draining (1-2 times weekly for dirty media, monthly for cleaner media).
Common transmitter wiring methods:
Standard Installation:
Connect the gas-liquid phase flanges to equipment flanges with gaskets and bolts. Ensure outlet pipes are clean and sealing surfaces intact before installation.
Note: Add valves between instrument and equipment flanges for easier maintenance.
Boiler-Specific Installation:
Special heat-dissipating structure protects transmitter from high temperatures. Ensure correct orientation with transmitter positioned below.
Display shows zero: Check 24V power supply, transmitter for shorts or quality issues
Current below 4mA: Verify liquid level position, transmitter adjustment, or potential defects
Current exceeds 25mA: Check for transmitter circuit shorts or excessive current adjustment
Display fluctuations: Examine actual liquid level stability, connection quality, or transmitter issues
No display change: Test transmitter functionality and check for pipe blockages or connection breaks
Slow response: Clean sensor from impurities or check for partial gas phase blockage
Measurement Tip: Always test 24V power supply by connecting voltmeter to power line terminals.
KSLV Selection Table for Intelligent Capacitive Fluid Level Gauge | |
---|---|
Product Type | 605 (No display model) 606 (No display model) |
Output Signal | 4-20mA signal output with LED display RS485 output |
Measuring Range | L500 (500mm) L800 (800mm) L1000 (1000mm) Lxxx (Custom lengths) |
Measuring Media | Water, diesel, or other specified media |
Example Configuration | KSLV 605 4-20mA L800 water NA |