Send Message
Home ProductsGas Detector Sensor

5% Measurement SF6 Gas Detector Sensor Module MEMS Light Source

5% Measurement SF6 Gas Detector Sensor Module MEMS Light Source

  • 5% Measurement SF6 Gas Detector Sensor Module MEMS Light Source
  • 5% Measurement SF6 Gas Detector Sensor Module MEMS Light Source
5% Measurement SF6 Gas Detector Sensor Module MEMS Light Source
Product Details:
Place of Origin: shanxi xi'an
Brand Name: Kacise
Model Number: KSS530
Payment & Shipping Terms:
Minimum Order Quantity: 1
Packaging Details: each unit has indicidual box and all boxes are packed in standard packages or customers requests available
Delivery Time: 5 work days
Payment Terms: T/T, Western Union, MoneyGram
Supply Ability: 1000 Pieces per Week
Contact Now
Detailed Product Description
Storage Temperature: -20-80℃ Operating Temperature: -20-60℃
Operating Humidity: 0-90%RH Work Pressure: 0.8-1.2 Atm
Supply Voltage: 12V Maximum Operating Current: 120mA
Range (customizable): 100ppm Measurement Accuracy: 0.5ppm Or ±2% True Value Is The Greater
T90 Of Pump Suction: 5S T90 Of Diffusion: 30S
Repeatability Of Zero: <±50 Ppm Repeatability Of 50%F.S.: <±5% Measurement
Life Span: 10 Years
High Light:

SF6 Gas Detector Sensor Module

,

5% SF6 Gas Detector Sensor

,

MEMS SF6 Gas Detector Sensor

KSS530 Infrared SF6 Gas Sensor Module

 

 

 

 

 

 

 

1. Overview

 

KSS530 is a gas sensor module using NDIR infrared absorption detection principle, which determines the concentration according to the absorption of SF6 gas at 10.6um. KSS530 adopts MEMS light source, optical cavity with special structure and dual-channel detector to realize spatial dual-optical path reference compensation, and microprocessor for signal acquisition, processing and output. KSS530 has good selectivity, high sensitivity, no oxygen dependence, long life, low power consumption; Built-in temperature sensor for temperature compensation; At the same time, it has UART, 485 output and analog voltage output, which is convenient for customers to various applications.

 

 

 

 

 

2. Technical Parameters

 

 

parameter symbol minimum Typical values maximum unit
Storage Temperature Tstg -20 - 80 °C
Operating Temperature TA -20   60 °C
Operating Humidity HA 0   90 % RH
Work Pressure PA 0.8   1.2 atm
Supply Voltage Vs 11 12 30 V
Maximum Operating Current Iavg 100 120 150 mA
Range (customizable)     100   ppm
Measurement Accuracy Acurracy   0.5ppm or ±2% true value is the greater   %vol
T90 Pump suction     5   second
Diffusion     30   second
Repeatability Zero     <±50   ppm
50%F.S.     <±5% measurement    
Life Span     10   year

 

3. Structural Dimension Drawing

 

 

5% Measurement SF6 Gas Detector Sensor Module MEMS Light Source 0

5% Measurement SF6 Gas Detector Sensor Module MEMS Light Source 1

 

 

 

4. Installation Instructions

The sensor is mounted with a positioning hole spacing of 64 mm and an aperture of 3 mm

The wiring socket spacing is 2.54 m m

 

5. Matters that should be paid attention to in maintenance

The sensor should be calibrated regularly, it is recommended that it be no more than 3 months, and calibration is not required if automatic calibration is turned on for long-term operation

Do not use the sensor for a long time in an environment with a high density of dust

Please use the sensor within the range of the sensor's power supply

 

6. Ordering Instructions

In order to be able to purchase the specific specifications required, please provide the following information

1) Sensor name

2) Measure the gas

3) Sensor range

For example, SW521R200, SF6, 0-100 ppm

7. Release Notes

In order to facilitate the better use of this product, V1.2 updates the calculation method of returning concentration value in the 4.3.2 MODBUS RTU protocol and the command description of reading concentration value after changing the address.

 

 

8. Ordering Information

 

Order information sheet
KSS530 KSS530 infrared SF6 gas sensor module
  xxxx The sensor measures the range of CO2 concentration in ppm, with a minimum value of 2000 and a maximum value of 50000 ppm.
2000 Range 200ppm (default).
10000 Range 10000ppm
50000 Range 50000ppm
  encode The reaction speed is divided into two types: fast and slow
S Slow (default).
Q fast
  encode Baud rate selection, support commonly used baud rate 2400 9600 19200 38400bps, 8 bits of data, 1 bit of stop bit, no check bit: Confirm special needs before ordering.
Custom Confirm the baud rate before ordering
2400 2400bps baud rate
9600 9600bps baud rate
19200 19200bps baud rate
38400 38400bps baud rate (default)
  encode Serial port protocol
Modbus-RTU Standard Modbus-RTU protocol (default).
Modbus-ASCII Standard Modbus-ASCII protocol
Modbus-Self Modbus private protocol
KSS530 -2000 -S -38400 -Modbus-RTU  

 

 

 

Contact Details

URL: www.kacise.com

Tel: +86-29-17719566736

Email: sales@kacise.com

Address: Tangyan South Road, Xi'an City, Shaanxi Province, China

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Appendix

 

Shorthand Full name
VOL 1% VOL refers to 1% of the volume of a particular gas in air.
PPM 1PPM means that the volume of a specific gas in the air accounts for one millionth.
O2 Oxygen molecules
LCD LCD display
RS485 Asynchronous serial port 485
DC direct current
AC Communication
PVC polyvinyl chloride

 

 

 

 

 

 

Contact Details
Xi'an Kacise Optronics Co.,Ltd.

Contact Person: Ms. Evelyn Wang

Tel: +86 17719566736

Fax: 86--17719566736

Send your inquiry directly to us (0 / 3000)

Contact

Address: i City, No11, TangYan South road, Yanta District, Xi'an,Shaanxi,China.

Factory Address:i City, No11, TangYan South road, Yanta District, Xi'an,Shaanxi,China.