Product Details:
Place of Origin: shanxi xi'an
Brand Name: Kacise
Model Number: KSS572
Payment & Shipping Terms:
Minimum Order Quantity: 1
Packaging Details: each unit has indicidual box and all boxes are packed in standard packages or customers requests available
Delivery Time: 5 work days
Payment Terms: T/T, Western Union, MoneyGram
Supply Ability: 1000 Pieces per Week
Contact Now
Detailed Product Description
Storage Temperature: -20-80℃ Operating Temperature: -20-60℃
Operating Humidity: 0-90%RH Work Pressure: 0.8-1.2 Atm
Supply Voltage: 12V Maximum Operating Current: 120mA
Detection Range (customizable).: 1000ppm Resolution: 1000ppm
Measurement Accuracy: ± 10ppm Or ±5% Truth Value %vol T90 Pipeline Type Of Pump Suction: 5S
T90 Pipeline Type Of Diffusion: 30S Repeatability Of Zero: Less Than ±50ppm
Repeatability Of Range: Less Than ±5%. Life Span: 10 Years
High Light:

Infrared SF6 Gas Sensor

,

1000ppm SF6 Gas Sensor

,

1000ppm Infrared sf6 sensor

KSS572 Infrared SF6 Sensor

 

 

 

 

 

 

 

 

 

1. overview

SF6 gas is widely used as an insulating medium and arc extinguishing gas in power equipment, especially in high-voltage circuit breakers, transformers, transformers, capacitors, arresters, fuses, etc. Leakage occurs, equipment pressure decreases, insulation capacity is reduced; Pollute and destroy the atmospheric environment, increase the greenhouse effect; Accumulation in low-level spaces, resulting in accidents such as lack of oxygen in the brains of staff and even rapid asphyxiation; Under the influence of partial discharge, high temperature and other factors, SF6 gas will produce highly toxic decomposition substances such as SF4, SF2, SOF2, etc.

KSS572 is a gas sensor module using NDIR infrared absorption detection principle. The concentration is determined according to the absorption of SF6 gas at 10.5um. The single-light source and dual-channel structure of MEMS light source, dual-channel pyroelectric detector and optical gas chamber are used to realize the reference compensation of the spatial dual optical path. Microprocessors perform signal acquisition, processing, and output, with temperature compensation and nonlinearity correction.

 

 

 

 

 

 

 

2. Technical parameters

 

 

parameter symbol minimum Typical values maximum unit
Storage Temperature Tstg -20 - 80 °C
Operating Temperature TA -20   60 °C
Operating Humidity HA 0   90 % RH
Work Pressure PA 0.8   1.2 atm
Supply Voltage Vs 11 12 30 V
Maximum Operating Current Iavg 100 120 150 mA
Detection Range (customizable). Ra   1000   ppm
Resolution Resolution   1000   ppm
Measurement Accuracy Acurracy   ± 10ppm or ±5% truth value   %vol
T90 Pipeline Type Pump suction     5   second
Diffusion   30   second
Repeatability Zero     Less than ±50   ppm
Range     Less than ±5%.    
Life Span     10   year

 

 

 

3. Structural dimension drawing

Unit: mm

1000ppm Infrared SF6 Gas Sensor High Resolution 0

Pump suction structure dimensional drawing

 

 

                                        1000ppm Infrared SF6 Gas Sensor High Resolution 1

 

Dimensional drawing of diffused structure

 

 

 

4. Installation instructions

The sensor is installed and positioned at a distance of 3.2mm according to the structural requirements

The wiring socket pitch is 2.54 mm

5. Matters that should be paid attention to in maintenance

The sensor should be calibrated regularly, it is recommended that it be no more than 3 months, and calibration is not required on the long-term operation side if automatic calibration is turned on

Do not use the sensor for a long time in an environment with a high density of dust

Please use the sensor within the range of the sensor's power supply

6. Ordering Instructions

In order to be able to purchase the specific specifications required, please provide the following information

1) Sensor name 2) Sensor range 3) Sensor measurement accuracy and output mode, etc

For example, SW521, 0-5000ppm, 4-20mA output

 

 

 

7. Order Information

 

Order information sheet
KSS572 KSS572 CO2 concentration sensor
  xxxx The sensor measures the range of CO2 concentration in ppm, with a minimum value of 2000 and a maximum value of 50000 ppm.
2000 Range 200ppm (default).
10000 Range 10000ppm
50000 Range 50000ppm
  encode The reaction speed is divided into two types: fast and slow
S Slow (default).
Q fast
  encode Baud rate selection, support commonly used baud rate 2400 9600 19200 38400bps, 8 bits of data, 1 bit of stop bit, no check bit: Confirm special needs before ordering.
Custom Confirm the baud rate before ordering
2400 2400bps baud rate
9600 9600bps baud rate
19200 19200bps baud rate
38400 38400bps baud rate (default)
  encode Serial port protocol
Modbus-RTU Standard Modbus-RTU protocol (default).
Modbus-ASCII Standard Modbus-ASCII protocol
Modbus-Self Modbus private protocol
KSS572 -2000 -S -38400 -Modbus-RTU  

 

 

 

9. Contact Details

URL: www.kacise.com

Tel: +86-29-17719566736

Email: sales@kacise.com

Address: Tangyan South Road, Xi'an City, Shaanxi Province, China

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Appendix

 

Shorthand Full name
VOL 1% VOL refers to 1% of the volume of a particular gas in air.
PPM 1PPM means that the volume of a specific gas in the air accounts for one millionth.
O2 Oxygen molecules
LCD LCD display
RS485 Asynchronous serial port 485
DC direct current
AC Communication
PVC polyvinyl chloride

 

 

 

 

Contact Details
Xi'an Kacise Optronics Co.,Ltd.

Contact Person: Ms. Evelyn Wang

Tel: +86 17719566736

Fax: 86--17719566736

Send your inquiry directly to us (0 / 3000)

Contact

Address: i City, No11, TangYan South road, Yanta District, Xi'an,Shaanxi,China.